ak series precise filter

Home » AK SERIES PRECISE FILTER
a
ak_017
ak_058
ak_220
ak_017
ak_058
ak_220

AK SERIES PRECISE FILTER

Advantages:

  •  The filter housing is made of aluminum alloy by die-casting and has a compact structure to ensure safe use.
  •  All housings are cleaned, degreased, and specially anti-corrosion treated before spraying to improve durability and applied to offshore platform operations.
  •  The precise threaded interface makes installation and maintenance more accessible and more convenient.
  •  All housings tested under working pressure 32bar for 96 hours, and the maximum burst pressure is 105bar.
  • Under the working condition of 1.5-80 ºC and pressure 16 bar, the body is guaranteed 15 years, and the service life of the Filter Element is 6000-8000 hours.

details

ak_line_filter_details_1
DP Gauge

The most popular application for differential pressure gauges is filtration monitoring. As a filter cartridge becomes obstructed with contaminants, the pressure between the inlet and outlet ports increases, and efficiency drops.

When the differential pressure reaches a specific limit, the operator knows it is time to change the filter, keeping the process running smoothly and efficiently and preventing damage to the system. Similarly, the operator can use the DP gauge to detect scale buildup in pipes and pumps.

High Quality Body

 All shells are cleaned, degreased and specially anti-corrosion treated before spraying to improve durability and can be applied to offshore platform operations. The precise threaded interface makes installation and maintenance easier and more convenient.

ak_line_filter_details_2
ak_line_filter_details_4
Sight Glass

Sight glass is made of unique materials, checks the blockage condition of the drainer 

Manual Bleed Valve

The pressure can be relieved when the Precision filter is replaced or overhauled by rotating the manual Bleed Valve. You can also drain when the Auto drain valve is blocked with the manual bleed valve.

ak_line_filter_details_5

Technical Specification

ModelPipe sizeFlow ratesDimension (mm)
L/Sm³/minscfmW(Width)D (Depth)H (Height)ABC(clearance for housing)
AK017RC1/2″16.7135.3897924640186118
AK025RC3/4″251.553897924640186118
AK030RC1/2″301.863.6897928040220158
AK035RC3/4″33.3270.6897928040220158
AK058RC3/4″46.72.898.912011037755276195
AK068RC1″603.6127.112011037755276195
AK080RC1″804.8169.512011047755377290
AK145RC1-1/2″1207.2254.212011047755377290
AK220RC2″20012423.716215167664566480
AK260RC2-1/2″233.314494.416215167664566480
AK330RC2″267.216564.816215198464875780
AK360RC2-1/2″317.319670.716215198464875780
AK405RC2-1/2″367.422776.620018975778634560
AK430RC3″467.628988.420018975778634560
AK620RC3″62037.21313.6200189101278889780
Technical requirements
Maximum operating pressure: 10 barg Maximum operating temperature: 80°C Minimum operating temperature:1.5°C
PressureBarg1235678910111213141516
Psig1529447387100116131145160174189203219232
Correction factor0.380.530.650.850.9311.071.131.191.231.311.361.411.461.51

Air Element Filtration:
Products are tested with the international advanced testing equipment based on standard ISO12500, which is equivalent to the standard ISO8573.

Filtration Grade      
PFAOAAAXACSARAAR
Particle removal (ISO12500-3)5μm1μm0.01μm0.01μm1μm0.01μm
Outlet oil aerosol concentration (ISO12500-1)5mg/m³0.6mg/m³<0.01mg/m³<0.001mg/m³<0.004mg/m³
Filtration performance of Particle (ISO12500-3)99.999+%99.999+%99.999+%99.999+%99.999+%99.999+%
Filtration performance of (ISO12500-1)50%80+%99.9+%99.99+%
Element spanlife6000 hours6000 hours6000 hours6000 hours2000-3000 hours4000-6000 hours4000-6000 hours
Precede withBefore  Air Dryerafter air dryerafter AOafter AAbefore AXafter desiccant dryerafter AR